Nhận sửa chữa, bảo dưỡng, tư vấn cung cấp mới biến tần của hãng Bonfiglioli
Bonfiglioli Active Series
Specifications
-
Main options
DC 24 V power supply output
•EM-IO-01: Expansion for 3 digital inputs, 2 relay outputs, 1 analog input, 1 analog output, system bus connection, DC 24 V power supply output
• EM-IO-02: Expansion for 3 digital inputs, 1 relay output, 1 analog input, 1 analog output, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-03: Expansion for 2 digital inputs, 1 relay output, 1 analog input, 2 analog outputs, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-04: Expansion for 2 digital inputs, 1 digital port (input or output), motor-PTC input, system bus connection, DC 24 V power supply output
Optional encoder & feedback evaluation:
• EM-ENC-01: TTL/HTL encoder input (2 channels), encoder emulation output (2 channels), 1 analog input, system bus connection, DC 5 V power supply output
• EM-ENC-02: TTL/HTL encoder input (2 channels), 1 digital port (input or output), 1 analog input, 1 analog output, system bus connection, DC 5 V power supply output
• EM-ENC-03: TTL/HTL encoder input (2 channels), system bus connection
• EM-ENC-04: TTL/HTL encoder input (3 channels), 1 relay output, 1 analog input, 1 analog output, 24 V power supply output, DC 5 V power supply output
• EM-ENC-05: TTL/HTL encoder input (3 channels), 1 analog input, 1 analog output, system bus connection, 24 V power supply output, DC 5 V power supply output
• EM-RES-01: Resolver input, encoder emulation output (2 channels), 1 analog input, system bus connection
• EM-RES-02: Resolver input, encoder emulation output (3 channels), 1 analog input
Optional PC software
VPlus for Windows with setup, terminal monitor, actual value window, and scope function
Accessories:
• Brake resistors Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
• Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system's EMC.
• Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation. -
Degree of protection
IP20 (EN 60529) -
Rated speed
0...599 Hz -
Certifications
UL508c -
Conformity
CE
EN61800 -
Power supply & Power range
ACT401:
0.55 - 132 kW / three-phase 360 - 480V / 50 - 60 Hz (± 10%)
ACT201:
0.55 - 9.2 kW / single or three-phase 200 - 240V / 50 - 60 Hz (± 10%) -
Software features
Main software features
• Programmable reference value channel
• Programmable start and stop characteristics
• Motor potentiometer
• Programmable S curve
• 4 data sets
• Auto startup and commissioning
• Auto reset after failure
• Auto start after power failure
• PL controller
• Programmable logic and timer functions
• Volume flow control
• Bumpless torque/speed changeover,
• Master/slave function with electronic gear,
• Simple positioning function,
• Mechanical brake control free of friction
• Index control
• Intelligent current limits
• Power failure control
• Comprehensive monitoring and protection capabilities
• High speed control
• Functions for lift, crane and winch applications
• 3 different brake management functions. -
Hardware features
• Integrated dynamic braking module
• DC link connection
• Standard HTL encoder interface
• Motor temperature monitoring
• Plug-in power terminals (up to 3kW)
• Plug-in and programmable control terminals
• 6 digital input, 1 multifunction input
• 1 digital output, 1 multifunction output
• 1 relay output (changeover contact) -
Mounting options
• Cabinet mounting for all sizes
• Optional feed-through mounting
• Optional DIN rail mounting frame size 1
• Optional ColdPlate mounting -
Motors
• Motor compatibility
• Two types of motors:
• Asynchronous AC motors
• Permanent magnet synchronous (brushless) motors -
TYPES & POWERS (ACT401)
Type | Power kW*
ACT401 - 05 | 0.55
ACT401 - 07 | 0.75
ACT401 - 09 | 1.10
ACT401 - 11 | 1.50
ACT401 - 12 | 1.85
ACT401 - 13 | 2.20
ACT401 - 15 | 3.00
ACT401 - 18 | 4.00
ACT401 - 19 | 5.50
ACT401 - 21 | 7.50
ACT401 - 22 | 9.20
ACT401 - 23 | 11.00
ACT401 - 25 | 15.00
ACT401 - 27 | 18.50
ACT401 - 29 | 22.00
ACT401 - 31 | 30.00
ACT401 - 33 | 37.00
ACT401 - 35 | 45.00
ACT401 - 37 | 55.00
ACT401 - 39 | 65.00
ACT401 - 43 | 75.00
ACT401 - 45 | 90.00
ACT401 - 47 | 110.00
ACT401 - 49 | 132.00 -
TYPES & POWERS (ACT201)
Type | Power kW*
ACT201 - 05 | 0.55
ACT201 - 07 | 0.75
ACT201 - 09 | 1.10
ACT201 - 11 | 1.50
ACT201 - 13 | 2.20
ACT201 - 15 | 3.00
ACT201 - 18 | 4.00
ACT201 - 19 | 5.50
ACT201 - 21 | 7.50
ACT201 - 22 | 9.20
Tại sao lại chọn chúng tôi???
=> Là một trong những đơn vị tiên phong trong ngành tự động hóa công nghiệp.
=> Đã và đang hợp tác với hơn 200 hãng uy tính khắp nơi trên thế giới - Và là đại lý của hơn 70 hãng
=> Đội ngũ kỹ sư được gửi đi đào tạo trực tiếp tại hãng hằng năm. Với kinh nghiệp dày dặn trong lĩnh vực sửa chữa các thiêt bị tự động hóa như: biến tần, servo motor, encoder, sensor, flowmeter, CPU, PC, Card, màn hình HMI, Modul, UPS, PLC,.... Đội ngũ kỹ thuật của chúng tôi sẽ hỗ trợ cho bạn 24/7 ( Tư vấn thiết bị, hướng dẫn - hỗ trợ lắp đặt, kiểm tra tình trạng - báo giá hoàn toàn miễn phí)
=> Thiết bị hay phụ kiện sửa chữa đều được nhập trực tiếp từ hãng, có COCQ chứng thực. Vậy nên bạn sẽ luôn được hỗ trợ về giá một cách tốt nhất.
=>Bảo hành 12 tháng với thiết bị cung cấp mới - 6 tháng với thiết bị sửa chữa - 1 đổi 1 nếu có lỗi phát sinh do nhà sản xuất
======>Liên hệ ngay với chúng tôi để được hỗ trợ.
Website: http://dichvusuabientan.com/
Gmail: tung@pitesco.com / nhat@pitesco.com
Mr Nhật: 0909.352.877
Mr Tùng: 0912300549