Sửa chữa - Cung cấp biến tần Bonfiglioli Active Cube chính hãng
Active Cube Series
Specifications
-
Main options
Optional keypad for easy setup, commissioning, Parameterization, copy function and diagnosis
• KP500: Removable keypad
• KPCMK: Cabinet mounting kit and handheld for keypad
Optional interface for communication with PC
• KP232: Serial communication interface that can be mounted & unmounted during operation, recommended for service personnel
• CM232: Serial communication interface that is installed during commissioning, recommended for continuous data logging or data exchange
• CM485: Serial communication interface that is installed during commissioning, recommended for continuous data logging or data exchange
• ISO-USB: USB to serial adapter, galvanic decoupled
Optional field bus communication:
• CM-CAN: CANopen
• CM-PDP: PROFIBUS
• CM232: Modbus ASCII & Modbus RTU for point-to-point connection
• CM485: Modbus ASCII & Modbus RTU via RS485 connection
• CM-DeviceNet: DeviceNet
• CM-EtherCAT®: EtherCAT®
• CM-PROFINET: PROFINET
• CM-Ethernet/IP: Ethernet/IP with one usable port as end-of-line device
• CM-Ethernet/IP-2P: Ethernet/IP with two usable ports (daisy chaining is possible)
• CM-Modbus/TCP: Modbus/TCP with one usable port as end-of-line device
• CM-Modbus/TCP-2P: Modbus/TCP with two usable ports (daisy chaining is possible)
• Ethernet VABus/TCP: VABus/TCP: with one usable port as end-of-line device
• Ethernet VABus/TCP-2P: VABus/TCP: with two usable ports (daisy chaining is possible)
Optional I/O Extension:
• EM-IO-01: Expansion for 3 digital inputs, 2 relay outputs, 1 analog input, 1 analog output, system bus connection, DC 24 V power supply output
• EM-IO-02: Expansion for 3 digital inputs, 1 relay output, 1 analog input, 1 analog output, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-03: Expansion for 2 digital inputs, 1 relay output, 1 analog input, 2 analog outputs, motor-PTC input, system bus connection, DC 24 V power supply output
• EM-IO-04: Expansion for 2 digital inputs, 1 digital port (input or output), motor-PTC input, system bus connection, DC 24 V power supply output
Optional encoder & feedback evaluation:
• EM-ENC-01: TTL/HTL encoder input (2 channels), encoder emulation output (2 channels), 1 analog input, system bus connection, DC 5 V power supply output
• EM-ENC-02: TTL/HTL encoder input (2 channels), 1 digital port (input or output), 1 analog input, 1 analog output, system bus connection, DC 5 V power supply output
• EM-ENC-03: TTL/HTL encoder input (2 channels), system bus connection
• EM-ENC-04: TTL/HTL encoder input (3 channels), 1 relay output, 1 analog input, 1 analog output, 24 V power supply output, DC 5 V power supply output
• EM-ENC-05: TTL/HTL encoder input (3 channels), 1 analog input, 1 analog output, system bus connection, 24 V power supply output, DC 5 V power supply output
• EM-RES-01: Resolver input, encoder emulation output (2 channels), 1 analog input, system bus connection
• EM-RES-02: Resolver input, encoder emulation output (3 channels), 1 analog input
• EM-RES-03: Resolver input, 3 digital inputs, 2 digital outputs, 1 analog input, system bus
• EM-ABS-01: Absolute encoder input (Hiperface, EnDat 2.1, SinCos), 3 digital inputs, 2 digital outputs, 1 analog input, system bus, DC 5...12 V power supply output
Optional PC software
• VPlus for Windows with motor setup, terminal monitor
• Actual value window
• Scope function
• Parameter Storage
Variant for functionality extension:
• Spindle
• Winding software
• Synthetic power supply
Accessories:
• Brake resistors Type BR: Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
• Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system's EMC.
• Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation. -
Degree of protection
IP20 (EN 60529)
-
Certifications
UL508c
STO (EN13849 / EN 61508) -
Conformity
CE
EN61800 -
Power supply & Power range
ACU410: 0.25 - 400 kW / three-phase 360 - 480V / 50 - 60 Hz (± 10%)
Parallel connection up to 1200 kW
ACU210: 0.25 - 9.2 kW / single or three-phase 200 - 240V / 50 - 60 Hz (± 10%)
ACU510: 160 - 400 kW / three-phase 525V / 50 - 60 Hz (± 10%)
Parallel connection up to 1200 kW
ACU610: 160 - 400 kW / three-phase 690V / 50 - 60 Hz (± 10%)
Parallel connection up to 1200 kW -
Software features
Main software features
• Positioning function standalone through table motion profiles
• Positioning function via field bus (Motion Control compatible to CiA DS402)
• Rotary table control
• Master/slave function with electronic gear
• Power failure control
• Functions for lift, crane and winch applications
• Spindle control
• Traverse function for winders
• Programmable reference value channel
• Programmable start and stop characteristics
• Motor potentiometer
• Programmable S curve
• 4 data sets
• Auto startup and commissioning
• Auto reset after failure
• Auto start after power failure
• PI controller
• Volume flow control
• Jerkfree torque/speed changeover
• Mechanical brake control free of friction
• Index control
• Intelligent current limits
• Comprehensive monitoring and protection capabilities
• High-speed control
• 3 different brake management functions -
Hardware features
• Integrated safe torque off (ACU410: STO SIL 3 / PL e) function
•External 24Vdc supply
•Integrated dynamic braking module
•DC link connection
•Standard HTL encoder interface
•Motor temperature monitoring
•Plug-in power terminals (up to 3kW)
•Plug-in and programmable control terminals
•6 digital inputs, 1 multifunction input
•1 digital output, 1 multifunction output
•1 relay output (changeover contact) -
Mounting options
Cabinet mounting for all sizes
Optional feed-through mounting
Optional DIN rail mounting frame size 1
Optional ColdPlate mounting
Optional Liquid Cooling mounting -
Output
0 ... 599 Hz
-
Motors
• Motor compatibility
• Asynchronous AC motors
• Permanent magnet synchronous (brushless) motors
• Reluctance motors -
Motor options
Motor Control
Control of asynchronous, synchronous motors and synchronous reluctance motors.
Control methods:
• V/f
• Field-oriented control with encoder
• Field-oriented control without encoder
• Reluctance motor control without encoder feedback, optionally with encoder feedback
Overload capacity:
• 100 % continuous output
• up to 150 % for 60 s
• up to 200 % for 1 s
Switching frequencies 2,4,8,12,16 kHz (availability depending on power size)
EMC filter integrated up to 9.2 kW (EN61800-3)
-
TYPES & POWERS (ACU 210)
Type | Size | Power kW*
ACU 210- 01 | 1 | 0.25
ACU 210- 03 | 1 | 0.37
ACU 210- 05 | 1 | 0.55
ACU 210- 07 | 1 | 0.75
ACU 210- 09 | 1 | 1.1
ACU 210- 11 | 2 | 1.5
ACU 210- 13 | 2 | 2.2
ACU 210- 15 | 2 | 3
ACU 210- 18 | 3 | 4
ACU 210- 19 | 3 | 5.5
ACU 210- 21 | 4 | 7.5
ACU 210- 22 | 4 | 9.2 -
TYPES & POWERS (ACU 410)
Type | Size| Power kW*
ACU 410- 01 | 1 | 0.25
ACU 410- 03 | 1 | 0.37
ACU 410- 05 | 1 | 0.55
ACU 410- 07 | 1 | 0.75
ACU 410- 09 | 1 | 1.1
ACU 410- 11 | 1 | 1.5
ACU 410- 12 | 2 | 1.85
ACU 410- 13 | 2 | 2.2
ACU 410- 15 | 2 | 3
ACU 410- 18 | 2 | 4
ACU 410- 19 | 3 | 5.5
ACU 410- 21 | 3 | 7.5
ACU 410- 22 | 3 | 9.2
ACU 410- 23 | 4 | 11
ACU 410- 25 | 4 | 15
ACU 410- 27 | 5 | 18.5
ACU 410- 29 | 5 | 22
ACU 410- 31 | 5 | 30
ACU 410- 33 | 6 | 37
ACU 410- 35 | 6 | 45
ACU 410- 37 | 6 | 55
ACU 410- 39 | 6 | 65
ACU 410- 43 | 7 | 75
ACU 410- 45 | 7 | 90
ACU 410- 47 | 7 | 110
ACU 410- 49 | 7 | 132
ACU 410- 51 | 7 | 160
ACU 410- 53 | 7 | 200
ACU 410- 51 | 8 | 160
ACU 410- 53 | 8 | 200
ACU 410- 55 | 8 | 250
ACU 410- 57 | 8 | 315
ACU 410- 59 | 8 | 355
ACU 410- 61 | 8 | 400 -
TYPES & POWERS (ACU 510)
Type | Size | Power kW*
ACU 510- 51 | 8 | 160
ACU 510- 53 | 8 | 200
ACU 510- 55 | 8 | 250
ACU 510- 57 | 8 | 315
ACU 510- 59 | 8 | 355
ACU 510- 61 | 8 | 400 -
TYPES & POWERS (ACU 610)
Type | Size | Power kW*
ACU 610- 51 | 8 | 160
ACU 610- 53 | 8 | 200
ACU 610- 55 | 8 | 250
ACU 610- 57 | 8 | 315
ACU 610- 59 | 8 | 355
ACU 610- 61 | 8 | 400
Tại sao lại chọn chúng tôi???
=> Là một trong những đơn vị tiên phong trong ngành tự động hóa công nghiệp.
=> Đã và đang hợp tác với hơn 200 hãng uy tính khắp nơi trên thế giới - Và là đại lý của hơn 70 hãng
=> Đội ngũ kỹ sư được gửi đi đào tạo trực tiếp tại hãng hằng năm. Với kinh nghiệp dày dặn trong lĩnh vực sửa chữa các thiêt bị tự động hóa như: biến tần, servo motor, encoder, sensor, flowmeter, CPU, PC, Card, màn hình HMI, Modul, UPS, PLC,.... Đội ngũ kỹ thuật của chúng tôi sẽ hỗ trợ cho bạn 24/7 ( Tư vấn thiết bị, hướng dẫn - hỗ trợ lắp đặt, kiểm tra tình trạng - báo giá hoàn toàn miễn phí)
=> Thiết bị hay phụ kiện sửa chữa đều được nhập trực tiếp từ hãng, có COCQ chứng thực. Vậy nên bạn sẽ luôn được hỗ trợ về giá một cách tốt nhất.
=>Bảo hành 12 tháng với thiết bị cung cấp mới - 6 tháng với thiết bị sửa chữa - 1 đổi 1 nếu có lỗi phát sinh do nhà sản xuất
======>Liên hệ ngay với chúng tôi để được hỗ trợ.
Website: http://dichvusuabientan.com/
Gmail: tung@pitesco.com / nhat@pitesco.com
Mr Nhật: 0909.352.877
Mr Tùng: 0912300549